Selection Guide
Data Acquistion Systems  
To start a new selection process click here.


  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
                                                                             
 Model  
D1000 and D2000
 
D3000 and D4000
 
D5000
 
DIN-100
 
H1700 Series
 
IBTx and IBTHx
 
IDR Series
 
iDRX
 
iFPX
 
INET Series
 
iPTX
 
iSE-TH
 
iTCX
 
iTHX-W
 
LCIC-1106A
 
OMB-CHARTSCAN-1400
 
OMB-DAQ-3000
 
OMB-DAQ-55/56
 
OMB-DAQBOARD-2000 Series
 
OMB-DAQSCAN-2000
 
OMB-DAQTEMP Series
 
OMB-MULTISCAN-1200
 
OMB-TEMPSCAN
 
OME-A-8111
 
OME-A-822PGL and OME-A-822PGH
 
OME-A-826PG
 
OME-PCI-1002 Series
 
OME-PCI-1202 Series
 
OME-PCI-1602 Series
 
OME-PISO-813
 
OMG-PCI-DIO Series
 
OMG-USB-DIO48
 
TC-08
 
TCIC
 
TJ-USB
 
USB-4711A
 
USB-4718
 
USB-4750
 
USB-4751 and USB-4751L
 
USB-4761
 Description  
OMEGABUS® Digital Transmitters
 
OMEGABUS Computer-to-Analog OutputModules
 
OMEGABUS Series Four Channel Sensor to Computer Interface Modules
 
Din Rail Mount Digital Transmitters
 
Digital I/O to Computer Interfaces RS-232 or RS-485 Compatible
 
iServer MicroServer™ Barometric Pressure, Temperature, and Humidity Transmitters
 
iSeries PID Controllers and Signal Conditioners
 
Programmable Signal Conditioners/Transmitters
 
Internet Counter iServer MicroServer
 
instruNet Series Direct Sensor to Data Acquisition
 
Virtual Chart Recorder Pressure and Temperature
 
Web-Based Remote Surveillance of Temperature and Humidity
 
Thermocouple Virtual Chart Recorder
 
Temperature and Humidity MicroServer
 
Load-Cells Interface Card For PC/AT or Compatibles
 
Portable Voltage and Temperature Recorder
 
1-MHz, 16-Bit USB Data Acquistion Modules
 
USB Data Acquisition Modules for Thermocouples Process Signals
 
High-Performance PCI-Based Data Acquisition Boards
 
Ethernet-Based Data Acquisition System
 
High Accuracy PCI Thermocouple/Multifunction Data Acquisition Systems
 
High Speed Isolated Temperature/Voltage Interface
 
High Speed Temperature & Process SignalMeasurement System
 
30 KS/s 12-Bit Analog and Digital I/O Board for the ISA Bus
 
125 KS/s 16-Channel 12-Bit Analog Input Board with Analog Output and Digital I/O for the ISA Bus
 
100 S/s 16-Channel 16-Bit Analog Input Board for the ISA Bus
 
110 KS/s 12-Bit Low Cost A/D Boards
 
110 KS/s 12-Bit High Performance Analog and Digital I/O Boards
 
100 KS/s and 200 KS/s 16-Bit High Performance Analog
and Digital I/O Boards
 
32-Channel Single-Ended Isolated Analog Input Board
 
High Performance Low Cost Digital I/O Boards for PCI Bus Computers 24, 32, 48 and 96 Channel Versions
 
USB Digital I/O Interface
 
8-Channel USB Thermocouple Data Acquisition Module
 
High-Speed 8-Channel Thermocouple Interface Card
 
Transition Joint Thermocouple Probe Features USB Interface and Free Recording and Logging Software
 
150 kS/S 12-Bit Multifunction USB Data Aquisition Module
 
8-Channel Thermocouple Input USB Data Acquisition Module
 
32-Channel Isolated Digital I/O USB Data Acquisition Module
 
48/24-Channel TTL Digital I/O USB Data Acquisition Modules
 
8-Channel Relay/Isolated DI USB Data Acquisition Module
 Starting Price  
£168
 
£184
 
£168
 
£94
 
£184
 
£198
 
£161
 
£168
 
£164
 
£790
 
£198
 
£332
 
£198
 
£198
 
£665
 
£1340
 
£935
 
£435
 
£401
 
£670
 
£1005
 
£1005
 
£1005
 
£157
 
£298
 
£405
 
£245
 
£348
 
£595
 
£211
 
£107
 
£214
 
£328
 
£385
 
£64
 
£365
 
£365
 
£164
 
£90
 
£184
 Interface Type  
RS232 or RS485 Depending on Model
 
RS232 or RS485 Depending on Model
 
RS232 or RS485 Depending on Model
 
RS485
 
RS232
 
Ethernet
 
Ethernet
 
RS485, Ethernet Option Available
 
Ethernet
 
PCI Card or PCMCIA Card
 
Ethernet
 
Ethernet
 
Ethernet
 
Ethernet
 
ISA Card
 
RS232, RS485, IEEE-488(optional)
 
USB
 
USB
 
PCI Card
 
Ethernet
 
PCI Card
 
RS232, RS485, IEEE-488
 
RS232, RS485, IEEE-488
 
ISA Card
 
ISA Card
 
ISA Card
 
PCI Card
 
PCI Card
 
PCI Card
 
PCI Card
 
PCI Card
 
USB
 
USB
 
USB, RS232, RS485
 
USB
 
USB
 
USB
 
USB
 
USB
 
USB
 Number of Analog Inputs  
Most Modules are Single Channel. Expandable to 124 Channels with Repeater
 
No Inputs - Use with the D3000/4000 if Inputs are Needed
 
4 Analog Input Channels Per Module. Expandable to 124 Channels with Repeater
 
Most Modules are Single Channel. Expandable to 247 Channels with Repeater
 
No Analog Inputs
 
1 Temperature and 1 barometric pressure input
 
1 Input per Module
 
Each iDRX has a single input. Up to 32 modules can be connected on a single bus
 
2
 
Each INET Box has 16 Single-Ended Inputs and 8 Differential Analog Inputs
 
1 Temperature 1 Pressure
 
2
 
1 Thermocouple
 
1 Temperature 1 Humidity
 
One Load Cell Input
 
Expandable to 64 Inputs
 
16 Single-Ended/8 Differential Expandable to 128 Inputs
 
OMB-DAQ-54 and OMB-DAQ-55 has 5 Differential/10 Single-ended Analog Inputs
OMB-DAQ-56 has 10 Differential/20 Single-ended Analog Inputs
Expansion Modules Available(for DAQ-55/56 only)
 
8 Differential or 16 Single-Ended Inputs(expandable to 256)
 
8 Differential or 16 Single-Ended Inputs expandable to 256 Voltage or 896 Thermocouple Channels
 
Models with 7 or 14 Thermocouple Inputs
7 Voltage Inputs
 
Expandable to 744 Inputs
 
Expandable to 992 Inputs
 
8 Single-Ended
 
16 Single-Ended or 8 Differential Input Channels
 
16 Single-Ended or 8 Differential Input Channels
 
32 Single-Ended/16 Differential Inputs
 
32 Single-Ended/16 Differential Inputs
 
32 Single-Ended/16 Differential Inputs
 
32 Single-Ended Inputs
 
No Analog Inputs
 
No Analog Inputs
 
8 Thermocouple Inputs
 
8 Thermocouple Inputs
 
1 Thermocouple with Integrated Probe
 
16 single-ended/8 differential Analog Inputs
 
8 Thermocouple, mV, V or mA Inputs
 
No analog inputs
 
No analog inputs
 
No analog inputs
 Analog Input Type  
Thermocouple(J,KT,E,R,S,B,C ), RTD, Thermistor, DC Volts, DC Current, Bridge, Frequency
 
 
Thermocouple(J,KT,E) Thermistor, DC Volts(100mV,1V,5V,10V,100V), DC Current,
 
Thermocouple(J,KT,E,R,S,B,C ), RTD, dc Volts, DC Current, Bridge, Frequency
 
 
Temperature, Barometric Pressure
 
Thermocouple(K, J, T, E, R, S, B, C, N, and J DIN.), dc Volts and Current, RTD, Bridge, Frequency, Digital I/O
 
Thermocouple(J,K,T,E,R,S,B,N J DIN), ac/dc Volts and Current, RTD, Frequency
 
Frequency, Pulse, Total, Batch, and Quadrature
 
Thermocouple(J,K,T,E,R,S,B,N, C, D, G), dc Volts and Current, RTD, Thermistor, Accelerometer, Bridge, Frequency, Digital I/O
 
Temperature, Pressure
 
Temperature, Relative Humidity and Dewpoint
 
Thermocouple( J, K, T, E, R, S, B, C, N, L )
 
Temperature and Humidity
 
Load Cell
 
Thermocouple(J,K,T,E,R,S,B,N), ac/dc Volts and Current
 
Thermocouple (J,K,T,E,R,S,B,N)
Voltge ranges from +/-100mV to +/-10Vdc
 
Thermocouple(J,K,T,E,R,S,N), dc Volts and Current
 
The card accepts DC voltages
With expansion panels, inputs include thermocouples, RTDs and frequency
 
Base unit accepts voltages from +/-156mVdc to +/-10Vdc
Thermocouples and other input types available with optional signal conditioners
 
Thermocouples( J, K, S, T, B, E, N, R), 0 to10V, 0 to 5V, 0 to 2.5V, 0 to1.25V, 0 to 0.625V, 0 to 0.3125V, ±10V, ±5V, ±2.5V, ±1.25V, ±0.625V, ±0.3125V, ±0.156V
 
Thermocouple(J,K,T,E,R,S,N), ac/dc Volts and Current
 
Thermocouple(J,K,T,E,R,S,N), RTD, dc Volts and Current
 
±5 V, ±2.5 V, ±1.25 V,±0.625 V,±0.3125 V
 
OME-A-822PGH: ±10 V,±5 V, ±0.5 V, ±0.05 V,±0.005 V
OME-A-822PGL:±10 V,±5 V, ±2.5 V, ±1.25V,±0.625 V
 
±10 V,±5 V, ±2.5 V, ±1.25V
 
OME-PCI-1002H:±5 V, ±0.5 V, ±0.05 V,±0.005 V
OME-PCI-1002L:±5 V, ±2.5 V, ±1.25V,±0.625 V
 
OME-PCI-1202H:±10 V,±5 V, ±0.5 V, ±0.05 V,±0.005 V
OME-PCI-1202L:±10 V,±5 V, ±2.5 V, ±1.25V,±0.625 V
 
10 V,±5 V, ±2.5 V, ±1.25V,±
 
Bipolar: ±10 V, ±5 V, ±2.5 V, ±1.25,V, ±0.625 V
Unipolar: 0-10 V, 0-5 V, 0-2.5 V, 0-1.25 V
 
 
 
Thermocouple(J, K, T, E, R, S, B and N)
 
Thermocouple(J, K, T, E, R, S) or +/-500 mV
 
K Thermocouple
 
Ranges from +/-0.625Vdc to +/-10Vdc
 
Thermocouple: J,K,T,E,R,S,B
Process: 0 to 15 mV, 0 to 50 mV, 0 to 100 mV, 0 to 500 mV, 0 to 1V, 0 to 2.5V, 0 to 20 mA, 4 to 20 mA
 
 
 
 Analog Input Sample Rate  
1 Samples/Second
 
 
1 Samples/Second
 
1 Sample/Second
 
1 Sample/Second
 
Charts updated as fast as 1 minute intervals
 
3 Samples/Second
 
1 Sample/Second
 
Frequncy ranges 1 Hz to 100 KHz
 
166 Ksamples/sec
 
Response Time is 5 seconds
 
Response Time is 4 seconds for relative Humidity and 5 seconds for temperature
 
Up to 12 Sample/Second at rated accuracy
 
1 Sample/Second
 
400/second After Filtering
 
147 Samples/sec
 
1,000,000 Samples/sec
 
80 Samples/sec
 
200Khz Samples/sec
 
200Khz Samples/sec
 
200 KSamples/sec(thermocouple channels have a 4Hz Filter)
 
147 Samples/sec
 
960 Samples/sec
 
30 KSamples/sec
 
125 KSamples/sec
 
100 KSamples/sec
 
110 KSamples/sec(max rate at low gain)
 
110 KSamples/sec(max rate at low gain)
 
OME-PCI-1602: 100 KSamples/s max.
OME-PCI-1602F: 200 KSamples/s max
 
10 KSamples/s max
 
 
 
10 Sampels/Second
 
400 Hz total throughput (50 Hz/channel)
 
2 Sampels/Second
 
150 KSamples/s max
 
10 Samples/sec
 
 
 
 Analog Input Resolution  
15 Bit
 
 
15 Bit
 
15 Bit
 
 
14 Bit(Temperature), 12 Bit(Humidity)
 
1°/0.1° for temperature models; 10 µV for process models, 10/1 µV for strain models
 
11-14 Bit Depending on Model
 
Not Applicable
 
14 Bit
 
Pressure:0.006 PSI
Temperature: 0.01°C
 
0.03% for RH and 0.01°C for temperature