Selection Guide
Data Loggers  
To start a new selection process click here.


  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
  Image
More Info
                                                                                                                     
 Model  
AD128
 
HH306
 
HH314
 
HH500P
 
HH611 Series
 
HH611A
 
HH83 and HH84
 
OM-2041
 
OM-320/420
 
OM-40 Series
 
OM-50 Series
 
OM-60
 
OM-63
 
OM-CP-LEVEL1000
 
OM-CP-LEVEL101
 
OM-CP-MICRORHTEMP
 
OM-CP-OCTPROCESS
 
OM-CP-OCTTEMP
 
OM-CP-OCTVOLT
 
OM-CP-PH101
 
OM-CP-PHONEPROCESS
 
OM-CP-PHONETEMP
 
OM-CP-PRHTEMP101
 
OM-CP-PROCESS101
 
OM-CP-PRTEMP1000
 
OM-CP-PRTEMP101
 
OM-CP-PRTRANS
 
OM-CP-PRTRANSIS
 
OM-CP-PULSE101
 
OM-CP-QUADPROCESS
 
OM-CP-QUADTEMP
 
OM-CP-QUADVOLT
 
OM-CP-RHTEMP1000
 
OM-CP-RHTEMP101
 
OM-CP-RTDTEMP101
 
OM-CP-SAFETEMP
 
OM-CP-SHOCK101
 
OM-CP-TC4000
 
OM-CP-TEMP100
 
OM-CP-TEMP1000P
 
OM-CP-THERMOVAULT
 
OM-CP-ULTRASHOCK101
 
OM-CP-VOLT101
 
OM-DAQPRO-5300
 
OM-EL Family
 
OM-EL-USB-1
 
OM-EL-USB-LITE-5
 
OM-ML
 
OM-NOMAD
 
OM-NOMAD-340
 
OM-PL Family
 
OM-PQR1010
 
OM-SC
 
OM-SL
 
OM-SP Series
 
OM-USCAN
 
OMB-LOGBOOK
 
OMP-MNL
 
OMP-MODL
 
RH32B-C2
 Starting Price  
£535
 
£124
 
£198
 
£399
 
£191
 
£251
 
£389
 
£530
 
£1875
 
£39.5
 
£46
 
£151
 
£50
 
£442
 
£375
 
£200
 
£670
 
£670
 
£670
 
£670
 
£401
 
£401
 
£200
 
£133
 
£435
 
£153
 
£435
 
£435
 
£133
 
£401
 
£401
 
£401
 
£267
 
£133
 
£267
 
£267
 
£401
 
£133
 
£73
 
£267
 
£670
 
£535
 
£133
 
£665
 
£111
 
£40
 
£127 (for 5 Pack)
 
£105
 
£90
 
£77
 
£62
 
£1000
 
£133
 
£144
 
£288
 
£194
 
£2580
 
£665
 
£1060
 
£235
 Number of Inputs  
8 Analog Inputs and up to 16 Digital Inputs
 
2
 
3
 
Dual Input
 
Up to 4 Depending on Model
 
Up to 4 Depending on Model
 
HH83 - 3 channels

HH-84(2 channels)
 
 
Up to 24 Depending on Input Modules
 
Up to 4 Depending on Model
 
1
 
Up to 2 Depending on Model
 
1
 
2
 
2
 
1 Temperature
1 Humidity
 
8
 
8
 
8
 
2
 
1
 
1 Thermocouple, 1 Ambient Temperature
 
1 Temperature, 1 Pressure, 1 Humidity
 
1
 
1 Temperature
1 Pressure
 
1 Temperature
1 Pressure
 
1
 
1
 
1
 
4
 
4 Thermocouple Channels and 1 Ambient Channel
 
4
 
2
 
1 Humidity
1 Temperature
 
1
 
1 Ambient
1 Thermocouple
 
3-axis
 
1 Ambient
1 Thermocouple
 
1
 
1
 
1
 
3-axis Shock
1 Temperature
1 Humidity
1 Pressure
1 virtual channel (shock vector sum)
 
1
 
8
 
1 or 2 Depending on Model
 
1
 
1
 
1
 
1 Temperature
1 Humidity
 
1
 
1 or 2 Depending on Model
 
2 Channels AC voltage
1 Channel AC Current
1 Channel DC Voltage
1 Channel Temperature
1 Channel Humidity
 
1
 
1
 
1 to 5 Channels Depending on Model
 
1 Internal Temperature and 1 with Optional External Sensor
 
16 Analog Inputs Expandable to 256
40 Digital I/O Expandable to 208
 
4 Analog Inputs and 1Digital Input
 
Expandable to 24 Analog Inputs and 48 Digital Inputs/Alarm Outputs
 
2
 Input Type  
Depending on Model
0-5Vdc 0-10Vdc Thermistor Digital Inputs
 
Type K Thermocouple
 
3 Inputs - Temperature and Humidity from Included Probe. Additional K Thermocouple Input
 
J,K Thermocouple
 
K Thermocouple
RTD
 
J,K ,T Thermocouple
RTD
 
HH-83 - Thermistor

HH-84
K, J, E or T Thermocouple
±mV, ±1Vdc
 
Thermocouples
DC Volt and Current
 
Thermocouples
RTD Thermistor
DC Volt and Current
Pulse Frequency
 
Thermistor
Relative Humidity
DC Voltage
DC Current
 
Contact Closure
Light On/Off
Motor On/Off
 
Pressure
Temperature
Relative Humidity
Model Dependent
 
Temperature
 
Water Level and Temperature(Automatic Atmospheric Pressure Compensation)
 
Water Level and Temperature
 
Temperature and Humidity
 
0 to 100 mA
 
J, K, T, E, R, S, B, N Thermocouple
 
-1 to 16vdc
 
1 Temperature
1 pH
 
0 to 100 mA
 
J,K,T,E,R,S,B,N Thermocouple and Ambient Temperature
 
Temprature
Pressure
Humidity
 
0 to 100 mA
 
Temperature and Pressure
 
Temperature and Pressure
 
Pressure
 
Pressure
 
Pulse, Frequency
 
-20.0 to 120 mA
 
J,K,T,E,R,S,B,N Thermocouple and ambient temperature
 
0 to 15 Vdc
 
Temperature Humidity

Dewpoint calculated in software
 
Temperature Humidity

Dewpoint calculated in software
 
2, 3, or 4 Wire 100 Ohm RTD
 
Ambient Temperature and K thermocouple
 
Shock/Acceleration
-50G to + 50G
 
J,K,T,E,R,S,B,N Thermocouple and ambient temperature
 
Temperature
-40 to 80°C (-40 to 176°F)
 
Temperature with integral probe
–100°C to 250 °C
 
J,K,T,E,R,S,B,N Thermocouple
 
Shock/Acceleration
Humidity
Pressure
Temperature
 
0 to 15 vdc
 
Voltage, Current, PT100 RTD, J, K, T Thermocouples, 2252Ω or 10 KΩ Thermistors, Frequency/Pulse Input
 
Model Specific:
Temperature
K Thermocouple
dc Voltage and Current
pH Frequency
 
Model Specific:
Temperature, Relative Humidity, Dewpoint, Voltage and Current
 
temperature
 
Temperature
 
Temperature and Humidity(model specific)
 
Temperature
 
Model Specific:
Temperature
Humidity
4 to 20mA
AC Voltage
AC Current
 
AC Voltage 80-50Vac

AC Current 0.2A to 1000A RMS with CT

AC Frequency

DC Voltage ±1 to ±52Vdc

Humidity
 
Temperature
DC Voltage 400 mV to 27 Vdc
4-20mA
Ambient Light
 
Model Specific

AC Voltage:Ranges 0-1Vac to 0-600Vac

AC Current: up to 600Aac with CT
DC Current:
4-20mA

DC Voltage:0-100mV, 0-10Vdc
Thermocouple:J,K,T
 
Depending on Model

Thermocouple J, K, T, E, R and S

0 to 1 and 0 to 10 Vdc

0 to 22 mA

Temperature and Humidity
 
Temperature
 
Base Unit Accepts Analog Volts, Milivolt and Digital I/O.

With Signal Conditioning
Thermocouples, RTD
Strain Gage
Frequency
Dynamic Voltage and Current
 
Analog Inputs are configurable for:
thermocouple J, K, T, E, R, S
DC Volt Ranges From ±20mV to ±30V
DC Current ranges from ±200µA to ±22mA

Digital Input
 
Thermocouple J, K, T, E, R, S

DC Volt Ranges from ±20mV to ±30V
DC Current ranges from ±200µ