Temperature Section
|
|
Test & Measurement Section
|
|
 |
 |
 |
 |
|
 |
|
|
|

|
 |
|
1/16 DIN Autotune Controller
Click to enlarge the image
|
|
 |
Dual 4-Digit Display |
 |
Adaptive Tuning |
 |
Autotune PID, PID, or On-Off Control |
 |
Thermocouple Input with 1° or 0.1° Resolution |
 |
RTD Input with 1° or 0.1° Resolution |
 |
Scalable Voltage and Current Inputs |
 |
Displays in °F, °C, or Engineering Units |
 |
Password Protection |
 |
Front-Panel Programming |
 |
Relay, DC Pulse, AC SSR, Voltage, or Current Output(s) Optional Features |
 |
Optional Analogue Re-Transmission Process Output |
 |
Tracking/Non-Tracking Alarms Additional Features |
 |
Loop Break Protection |
 |
Min/Max Indication |
 |
Auto/Manual Operation |
 |
Percent Output Indication |
 |
Single-Segment Ramp and Soak |
|
 |
 |
 |
 |
 |
| Last 10 Viewed Products |
[X] |
|
 |
 |
 |
 |
|
 |
|
|
View all of our related products Temperature and Process Controllers and Power Switching Devices
|
 |
|

|
The CN76000 1/16 DIN controllers provide economical
control for a wide variety of processes, including
heating, cooling, and heat/cool. When used with the
proper transmitters, these devices can also control
pressure, flow, humidity, motion, or pH. The front
panel is NEMA 2, 3R, and 12 rated for waterproof
protection and is corrosion resistant.
The sophisticated design of the CN76000 incorporates
the latest microprocessor and surface mount
technology, compressing an unprecedented number of
standard features into a compact 1/16 DIN package. The
user can program control functions from the front
panel; input types are DIP switch selectable. Multiple
tuning modes allow the user to select from 3 standard
tuning presets, manual tuning, or autotuning.
Standard features include self-diagnosis with fault
indication. Non-volatile memory retains all process
parameters when power is off, without battery backup.
Settings for the optional alarm are configurable. The
alarm action may be defeated on startup, or until the
process value exceeds the alarm setpoint. The power
interrupt feature will reset on power-up if the alarm
condition no longer exists.
Other standard features include min/max storage and
display, auto/manual control, percent output indication,
ramp and soak operation, 4 user-selectable security
levels with password protection, and jumper-selected
5 Vdc pulse output to drive external solid state relays.
|
|
|
To Order |
|
|
Note:
Each unit supplied with mounting bracket and complete operator's manual. *These outputs are logic jumper selectable between relay and DC pulse, or between DC pulse and AC SSR.
|
|
|
|
|
|
|
Related Links
|
|
|
Keywords: CN76000 1/16 DIN Autotune Controller
|
|
|
|
| |
|