iTHX-SD: Record Years of Data on Removable SD Memory Cards |
 |
Use Your Favourite Web Browser - No Special Software Required |
 |
Measures Temperature, Relative Humidity & Dew Point |
 |
Web Server |
 |
Email Alarms |
|
 |
 |
 |
 |
 |
| Last 10 Viewed Products |
[X] |
|
 |
 |
 |
 |
|
 |
|
|
View all of our related products Relative Humidity Measurement Instruments
|
 |
|

|
View Temperature + Humidity with a Web Browser
The OMEGA® iTHX transmitter lets you monitor and record Temperature,
Relative Humidity and Dew Point over an Ethernet network or the Internet with no
special software except a Web browser.
The OMEGA® iTHX serves Active Web Pages to display real time readings,
display charts of temperature and humidity, or log data in standard data
formats for use in a spreadsheet or data acquisition program such as Excel or
Visual Basic.
Adjustable Charts
The JAVA™ Applet chart scales are fully adjustable in real-time. For example,
the chart can display one hour, one day, one week, one month or one year.
Temperature and humidity can be charted across the full span or within any narrow range.
The virtual chart viewed on the web page is a JAVATM Applet that records a chart over the LAN or
Internet in real time. With the OMEGA® iTHX , there is no need to
invest time and money learning a proprietary software program to log or chart the data.
Display and Chart Two Channels
The iTHX transmitters come complete with a temperature and humidity probe for measurement of a single location.
With the addition of a second probe, the iTHX transmitter can measure and display humidity, temperature and dew
point in a second location up to ten feet away.
The transmitter can display and chart absolute measurements in both locations,
or a differential measurement between the two locations. The second probe requires
no change to the basic iTHX transmitter hardware.
A second probe can be added at the time of purchase or in the future. OMEGA offers a choice of
industrial probes in 50mm and 125mm lengths, and a wand style for ambient indoor applications.
A simple DB-9 "Y" connector is available for adding a second probe to models
iTHX-W and iTHX-SD.
No connector is required to add a second probe to the DIN rail mounted
iTHX-2.
|
|

Display of Two Channels on Read Sensor Web Page

Industrial Probes :iTHP-5 and iTHP-2
|
Award-Winning Technology
The OMEGA® iTHX is simple to install and use, and features OMEGA's award-winning
iServer technology that requires no special software except a Web Browser.
The iTHX connects to an Ethernet Network with a standard RJ45 connector and sends data in
standard TCP/IP packets. It is easily configured with a simple menu using a Web Browser and
can be password protected. From within an Ethernet LAN or over the Internet, the user simply
types its IP address or an easy to remember name such as "Cleanroom 5" or "Server Room"
in any Web Browser, and the iTHX serves a Web Page with the current readings.
Email Alarms
All OMEGA® iTHX models that are on a LAN that is connected to the Internet can trigger an alarm that can be sent by email to a user
or a distribution list anywhere in the world, including text messages to cell phones and PDA's.
Typical Applications
The OMEGA® iTHX is great for monitoring temperature + humidity in applications such as:
clean rooms, computer rooms, HVAC systems, pharmaceutical and food processing and storage,
hospitals, laboratories, semiconductor fabs, electronic assembly, warehousing, museums,
manufacturing, greenhouses, farm animal shelters, and many more.
NEW iTHX-SD with SD Flash Memory and LCD Display
The OMEGA® iTHX-SD with LCD display, adds several valuable features in addition to the backlit local display of
temperature and humidity. The iTHX-SD model comes complete with a removable 2 GB SD Flash Memory card that can store
up to seven years of readings taken at ten second intervals.
The data being recorded on the SD card can be read with a standard card reader or remotely over an Ethernet network or the Internet.
With data being recorded on the SD card, a failure on the Ethernet network will not interrupt the data record.
|
|
|
Alarm Relays
The OMEGA® iTHX-SD features two 1.5 Amp relays. With the easy Web-based setup page, the two relays can be
programmed for any combination of temperature or humidity, and high or low set points.
The relays can also be programmed to remain latched and require a manual reset if a limit is exceeded.
Battery Backup
The OMEGA® iTHX-SD comes with a universal 100 to 240 Vac adapter. A standard 9 Volt
Alkaline battery (also included) allows the device to log data for up to 2 days without external ac power.
OMEGA iServer products are designed and manufactured in the U.S.A.
Specifications
Sensor Specifications
|
Relative Humidity (RH)
Accuracy/Range: ±2% for 10 to 90%
±3% for 5 to 10% and 90 to 95%
±4% for 0 to 5% and 95 to 100%
Non-linearity: ±3%
Hysteresis: ±1% RH
Response Time: 8 seconds, tau 63%
Repeatability: ±0.1%
Resolution: 0.1%, 12 bit
|
|
Temperature(T)
Accuracy/Range*:
Wand Probe:
±0.5°C ( ±1°F) for 5°C to 45°C (41°F to 113°F);
±0.5° to 1°C ( ±1° to 2°F) for 0° to 5°C and 45° to 70°C
(32° to 41°F and 113° to 158°F)
Industrial Probe:
±0.5°C ( ±1°F) for 5° to 45°C (41 to 113°F);
±0.5° to 1.5°C (±1° to 2.7°F) for -40° to 5°C and 45° to 124°C
(-40° to 41°F and 113° to 255°F)
*Note: extended temperature range is for Industrial probe only, the iServer's operating temp. is 0 to 70 °C.
Response Time: 5 to 30 seconds, tau 63%
Repeatability: ±0.1°C
Resolution: 0.1°C, 14 bit
|
Physical Dimensions
Wand Probe iTHP-W-6:
19.1mm Diameter x 198mm Long (0.75" x 7.8")
Cable with DB9 connector: 152mm Long (6")
Cable operating temperature: 0 to 80°C (32 to 176°F)
Industrial Probe iTHP-2, iTHP-5:
16mm Diameter x 51mm Long (0.63" x 2") or
16mm Diameter x 137mm Long (0.63" x 5")
Cable with DB9 connector or stripped wire leads: 0.9m Long (3') or
Cable with DB9 connector or stripped wire leads: 3m Long (10')
Cable operating temperature: -40 to 125°C (-40 to 257°F)
iServer Specifications
Interfaces
Ethernet (RJ45): Fixed or autonegotiating 10/100BASE-T, Auto MDI/MDIX for iTHX-SD;
10BASE-T for iTHX-W, iTHX-2
Sensor: Digital 4-wire (DB-9) for iTHX-W, iTHX-SD;
removable 8 posistion screw terminals for iTHX-2
Supported Protocols
TCP, UDP, SNMP, SMTP, NTP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet for iTHX-SD;
TCP, UDP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet for iTHX-W, iTHX-2
LCD Display
16 Digits 6mm (0.23 in.) for iTHX-SD
SD Flash Memory Card
2 GB card: 8 months of data storage at 1 seconds recording intervals, or 7 years at 10second intervals for iTHX-SD
Relay Outputs
Two Relays 1.5A @ 30 Vdc for iTHX-SD
Management
Device configuration and monitoring through embedded WEB server (Fig.1)
Embedded WEB Server
Serves WEB pages containing real-time data (Fig. 2)
and live updated charts within definable time intervals (Fig. 3).
Power
Power Input: 9 to 12 Vdc iTHX-W, iTHX-SD
Consumption: 2.5 W max.for iTHX-W; 3.5W for iTHX-SD
Safety Qualified ac power adapter:
Nominal Output: 9 Vdc @ 0.5A included for iTHX-W, iTHX-SD
Input: 100 to 240 Vac, 50/60 Hz
Battery: 9Vdc, Alkaline for iTHX-SD
Power Input:10 to 32 Vdc iTHX-2
Consumption: 2.5 W max.
Switching Power Supply (iDRN-PS-1000) sold separately for iTHX-2
Environmental
Operating Temperature: 0 to 70°C (32 to 158°F)
Storage Temperature: -40 to 125°C (-40 to 257°F)
Power Adapter Operating Temperature: 0º to 40ºC (32º to 104ºF)
Battery Operating Temperature: -18 to 55°C (0 to 131°F)
Packaging
Material: Steel metal case with wall mount bracket for iTHX-SD;
Valox 364 PBT case with wall mount bracket for iTHX-W;
Polycarbonate case with DIN Rail mount for iTHX-2
Dimensions: 27.4H x 66W x 93D mm (1.08 x 2.60 x 3.67 in) iTHX-W
39H x 62W x 90D mm (1.54 x 2.42 x 3.56 in) iTHX-SD
90.2H x 25.1W x 115.0Dmm (3.54 x 0.99 x 4.53 in) iTHX-2
Weight: 0.18 kg (0.4 lbs.) iTHX-W
0.389 kg (0.86 lbs.) iTHX-SD
0.113 kg (0.25 lbs.) iTHX-2
|
|
|
To Order |
|
|
Note:
* The iTHX-W and iTHX-2 has 2 channels. Each channel consists of a single temperature and humidity probe. Two channel models can accept two probes, that is, two temperature and two humidity readings. The second probe is provided optionally. In order to connect the second probe the DB9-Y adaptor is required.
|
|
|
|
|
|
|
Related Links
|
|
|
Keywords: iServer Temperature + Humidity Ethernet Transmitter
microserver
webserver
|
|
|
|
| |
|