Omega.co.uk - Omega Engineering Limited, Manchester, United Kingdom M44 5BD - Your Single Source for Process, Measurement and Control.

Free Phone 0800 488 488 or International +44(0) 161 777 6611
FREE PHONE 0800 488 488
INTERNATIONAL +44(0) 161 777 6611
France  Netherlands  Czech Republic  Germany  United States of America   
Temperature | Pressure, Strain & Force | Data Acquisition | Flow & Level | pH & Conductivity | Electric Heaters | Automation
Search By            
 Ask us a question    (0 items, £0.00) 
Omega.co.uk Home Quick Order Products Free Handbooks and Encyclopaedia's Omega Info
 All Products  Data Acquisition Products  Wireless Transmitters and Receivers  Product Details...
Data Acquistion Section
BSoftware
D1Input Boards/Cards
D2Output Boards/Cards
D3Digital I/O Boards/Cards
D4Communication Boards/Cards
EDataloggers
FRecorders
GAlarm Systems
HSignal Conditioners
JCommunications & Converters
Ethernet, USB & Wireless Section
CEthernet & USB Systems
KWireless Instrumentation


New New Data Acquistion, Ethernet, USB & Wireless Products
View all of our new products

Can't find what you are looking for?
Ask us a question

Industrial Wireless Sensors and Transmitters

Model(s): zED-P Series

Model Shown: zED-TP1-P £ 131.00
Your chosen country
GREAT BRITAIN
This allows us to provide accurate pricing in British Pounds

Industrial Wireless Sensors and Transmitters : zED-P Series
Industrial Wireless Sensors and Transmitters
Click to enlarge the image

Transmitters have a rugged, IP65 enclosure

Sensors for temperature, humidity and barometric pressure

Analogue inputs for process voltage and current

Dual thermocouple inputs

Receiver connects to an Ethernet network and serves it's own web pages with measured values

Email Alarms

No special software required - just a standard web browser

View all of our related products  Wireless Transmitters and Receivers
1 Year Warranty New CE IEC Specs Scroll below to order

These rugged OMEGA zED-P Series wireless transmitters are available with built-in sensors for temperature, humidity and barometric pressure, or inputs for thermocouples and process voltage and current.

The radio is an IEEE 802.15.4 compliant transmitter operating at 2.4 GHz.

Wireless sensors transmit up to 1000m --without obstructions or interferences to a zSeries receiver or wiSeries meter-controller. The receivers and controllers connect directly to an Ethernet network and the Internet and serve active Web Pages to display and chart the data in a standard web browser.

Alarms can be sent by email to a single user or to a group distribution list, including text messages to mobile phones.

These wiSeries wireless sensors are designed for demanding industrial applications indoors and harsh outdoor environments. The electronics are protected in a rugged weatherproof polycarbonate IP65 (NEMA4) rated housing. The industrial sensors are supplied with 3 metres of cable.



Wireless Sensors and Transmitters

Wireless sensors are available with external probes appropriate for an almost unlimited variety of industrial and commercial applications. Wireless transmitters are available for thermocouple or process voltage and current inputs.

Wireless sensor/transmitters run on either batteries or AC power. The battery version (zED-DCELL) comes with two alkaline D-Cell batteries that can last for years. The AC version (zED-P, zED-LCD) comes with a 5 VDC universal AC adapter that operates on any voltage worldwide (110-240 VAC). Should AC power fail, the unit can operate on a 3.6V ultra-long-life lithium backup battery (included). It can run on battery power for days, weeks, or months depending on the user's settings.

Alarms and Email
The wiSeries wireless sensor system can trigger an alarm if variables go above or below a set point that you determine. Your alarm can be sent by email to a single user or to a group distribution list, including text messages to mobile phones and PDA’s. The OMEGA "MailNotifier" software is a free and easy program for this application.

Embedded Web-Server
The OMEGA wiSeries wireless sensor system is easy to install, simple to operate, and features OMEGA’s award-winning iServer technology with an Embedded Web Server that requires no special software. It serves its own web pages wich can be viewed with your chosen web browser.

Charts and Graphs
The OMEGA wiSeries system serves Active Web Pages to display real time readings and charts. You can also log data in standard data formats for use in a spreadsheet or data acquisition program such as Excel or Visual Basic.

OMEGA offers a free and easy to use program for logging data to Excel. The virtual chart viewed on the web page is a JAVA™ Applet that records a chart over the LAN or Internet in real time. With the OMEGA wiSeries system there is no need to invest time and money learning a proprietary software program to log or chart the data.
Chart scales are fully adjustable in real-time. For example, the chart can display one minute, one hour, one day, one week, one month or one year. Temperature and humidity can be charted across the full span (-40 to 125°C, and 0 to 100% RH) or within any narrow range such as (20 to 30°C). OMEGA offers an OPC Server software that makes it easy to integrate the wiSeries wireless sensor system with many popular Data Acquisition and Automation programs offered by OMEGA, NEWPORT, Wonderware, iConics, Intellution, Rockwell Automation, and National Instruments, among others.

Specifications

External Sensors
Temperature
Accuracy/Range (extended temperature ranges for external probes only):
zED-TP1-P/-LCD/-DCELL; zED-TP2-P/-LCD/-DCELL
±0.5ºC for 10º to 85ºC; ±1ºC for -40º to 10ºC and 85º to 125ºC

zED-BTHP-P/-LCD/-DCELL; zED-THP-P/-LCD/-DCELL
±0.5ºC for 0ºC to 45ºC; ±1ºC for -18º to 0ºC and 45º to 70ºC
±2ºC for -40º to -18ºC and 70º to 124 ºC

zED-BTP-P/-LCD/-DCELL
±0.8ºC @ 20ºC; ±2ºC for -40º to 85ºC

Resolution: 0.1ºC
Repeatablilty: ±0.1ºC, for -BTHP, -THP (zED-P/-LCD/-DCELL)

Relative Humidity
Accuracy/Range:
zED-BTHP-P/-LCD/-DCELL; zED-THP-P/-LCD/-DCELL
±2% for 10 to 90%; ±3% for 0 to 10% and 90 to 100%
Hysteresis: ±1% RH
Non-linearity: ±3%
Repeatability: ±0.1%
Resolution: 0.1%

Barometric Pressure
Accuracy/Range:
zED-BTP-P/-LCD/-DCELL; zED-BTHP-P/-LCD/-DCELL;
±2 mbar for 10 mbar to 1100 mbar (1 KPa to 110 KPa)
Resolution: 0.1 mbar

Industrial Probe:
SS 316 housing, 137mm x Ø16mm for
zED-BTP-P/-LCD/-DCELL; zED-BTHP-P/-LCD/-DCELL; zED-THP-P/-LCD/-DCELL
Stick Probe:
ABS tubing, 152.4 mm x Ø6.35 mm for zED-TP1-P/-LCD/-DCELL
Lug Mounted Probe:
Copper tubing, 53.4 mm x Ø 7.92mm; mounting hole Ø 4.72mm
for zED-TP2-P/-LCD/-DCELL
Cable Dimensions and Operating Temperature:
3 m long x Ø 2.62 mm -80º to 200ºC
for zED-THP-P/-LCD/-DCELL; zED-TP1-P/-LCD/-DCELL; zED-TP2-P/-LCD/-DCELL
3 m long x Ø 4.45 mm -55 to 105ºC
for zED-BTP-P/-LCD/-DCELL; zED-BTHP-P/-LCD/-DCELL


Analogue and Thermocouple Inputs
Process Voltage and Current Inputs
Voltage Input: Differential; bipolar; ±100 mV, ±1 V, ±10 V
Input Impedance: 400 kΩ
Current Input: Differential; bipolar; ±20 mA (5 Ω load)
Accuracy: ±0.1% Full Range @ 25°C
Reading Rate: Periodic (1 sample/update) or continuous (20 samples/second)
A/D Conversion: Sigma-Delta
Resolution: 16 bits
Temperature Coefficient: ±50 ppm/°C
Common Mode Rejection: 105 dB
Normal Mode Rejection: 98 dB
Warm-Up to Rated Accuracy: 30 minutes
Thermocouple Inputs
Temperature Range: refer to Thermocouple Chart
Temperature Accuracy: refer to Thermocouple Chart
Temperature Stability: 0.08°C/°C
Temperature Coefficient: ±25 ppm/°C
Thermocouple Cold End Tracking: 0.1°C/°C
Thermocouple Lead Resistance: 100 Ω max.
Thermocouple Type (ITS 90):
J, K, T, E, R, S, B, C, N, L (DIN J)
Warm-Up to Rated Accuracy: 30 minutes


General
Environment (Transmitters)
Operating Temperature: -20º to 70ºC for zED-P
Operating Temperature: -18º to 55 ºC for zED-DCELL
Operating Temperature: -10º to 60ºC for zED-LCD
Power Adapter Operating Temperature: 0º to 40ºC for zED-P, zED-LCD
Enclosure Dimensions: L: 136 x W: 82 x D: 39 mm
Enclosure Material: Polycarbonate
Enclosure Protection: IP65 (NEMA 4)

Wireless Communication
Standard: IEEE 802.15.4, DSSS
Frequency: 2.4 GHz (2400 to 2483.5 MHz), 16 channels
Network Topology: Star Topology
Range: up to 1000 m without obstructions or interference.

Approvals: FCC: Part 15C. CE: EMC 2004/108/EC, LVD 2006/95/EC, RTT&E 1999/5/EC.

Software: iConnect (configuration software for the Ethernet interface), iLog (Excel-based for data logging),
and Mail Notifier (email alarm notification software)
Power
(zED-x-P, ZED-x-LCD)

Input: 5 Vdc, 0.8W max
ac Power Adapter (included)
Nominal Output: 5 Vdc @ 0.6 A
Input: 100 to 240 Vac, 50/60 Hz
Back-up Battery: one 3.6 Vdc lithium, supplied
Lifetime: Estimate 2 years with frequency of 1 reading per 2 minutes; 7 months for -TC option
(zED-VI-P, ZED-VI-LCD)
Input: 9 Vdc, 1.2W max
ac Power Adapter (included)
Nominal Output: 9 Vdc @ 0.5 A
Input: 100 to 240 Vac, 50/60 Hz
Back-up Battery: one 3.6 Vdc lithium, supplied
Lifetime: Estimate 2 years with frequency of 1 reading per 2 minutes; 7 months for -VI option
(zED-DCELL)
Battery: two D-cell Alkaline 1.5 Vdc, supplied
Lifetime: Estimate of 5 years with frequency of 1 reading per 2 minutes

Note: A complete wireless system requires at least: one transmitter (zED-x-P) and one Coordinator/Receiver (wi8xx-zT, wiDR-zT or zCDR).

Back to top  

To Order

      Specify Model Number.
 Quantity   Part Number   Availability   Price  Description   RoHS 
 Transmitters and End Devices
   zED-TP1-P  In Stock  £131.00    

Wireless temperature sensor with stick probe, ac powered

 
   zED-TP2-P  1 Week  £131.00    

Wireless temperature sensor with lug mount probe, ac powered

 
   zED-THP-P  In Stock  £161.00    

Wireless temperature and humidity sensor, ac powered

 
   zED-BTHP-P  1 Week  £198.00    

Wireless barometric pressure, temp and humidity sensor, AC powered

 
   zED-BTP-P  1 Week  £164.00    

Wireless barometric pressure and temperature sensor, ac powered

 
   zED-TC-P  1 Week  £161.00    

Wireless transmitter with Dual thermocouple input, AC powered

 
   zED-VI-P  1 Week  £161.00    

Wireless transmitter with analogue input, AC powered

 
   zED-TC-DCELL  1 Week  £161.00    

Wireless transmitter with dual thermocouple input, battery powered

 
   zED-VI-DCELL  1 Week  £161.00    

Wireless transmitter with analogue input, battery powered

 
   zED-TC-LCD  1 Week  £194.00    

Wireless transmitter with dual thermocouple input, AC powered, LCD display

 
   zED-VI-LCD  1 Week  £194.00    

Wireless transmitter with analogue input, AC powered, LCD display

 
 Receivers and Scanner/Controllers
   zCDR-VI  1 Week  £131.00    

Receiver, which can support up to 32 analogue input transmitters

 
   zCDR  In Stock  £131.00    

Receiver, which can support up to 32 sensor/transmitters

 
   wi833-ZT  1 Week  £265.00    

Scanner/controller with 2 relays, which can support up to 8 temperature transmitters

 
   wiDR22-ZT  1 Week  £265.00    

DIN rail monitor/controller with 2 solid state relays (SSRs), supports up to 8 temperature transmitters

 
   wiDR44-ZT-DC  1 Week  £281.00    

DIN rail monitor/controller with 2 pulsed 10 Vdc @ 20 mA (for use with external SSR) , supports up to 8 temperature transmitters

 
 Calibration Options
   CAL-3-HU  1 Week  £90.00    

Traceable calibration certificate; three humidity points: 25%, 50%, 75%, 1 temperature point of 25°C

 
   CAL-3-HU-P-T  2 Weeks  £168.00    

Traceable calibration certificate; three humidity, barometric pressure, and temperature points

 
   CAL-3-P  1 Week  £84.00    

Traceable calibration certificate; three barometric pressure points, and temperature 25°C

 
   CT485B-CAL-KIT  In Stock  £50.00    

Calibration kit, 33% and 75% RH standards

 
 Accessories
   OPC-SERVER LICENSE  1 Week  £198.00    

OPC server software

 
   
Note:

A complete wireless system requires at least: one transmitter (zED-x-x) and one Coordinator/Receiver (wi8xx-zT, wiDR-zT or zCDR).


Back to top  

Related Links

  Product Spec Sheet
 Product Spec Sheet in Adobe Acrobat Document Format
 Product Spec Sheet: zED-P_Series.pdf  Download & View zED-P_Series.pdf - Complete Product Specifications
Keywords:

wireless sensor, wireless measurement, temperature, humidity, barometric pressure, thermocouple, thermocouples, analogue, process, voltage, current, analog, telemetry

Back to top  
 
Search By            
OMEGA, Safe & Secure  Verisign Secured.TM.Secure methods of payment by Amex (American Express), Visa or Mastercard
  Copyright 2003-2010 | Omega Engineering Limited | OMEGA Privacy Statement MMV | 72 
Automation |  Accelerometers |  Calibrators |  Chart Recorders |  Cartridge Heaters |  Cryogenics |  Data Loggers |  Data Capture & Recording |  Dial Thermometers |  Fibre Optics |  Flexible Heaters |  Flowmeters |  Glass Bulb Thermometers |  Humidity Measurement |  Hygienic |  Immersion Heaters |  Infrared Thermometers |  Level Measurement |  Load Cells |  Magnetic Flow Meters |  Panel Meters |  Pressure Gauges |  Pressure Transducers |  PT100 |  Rotameters |  RTD |  Sanitary |  Strip Heaters |  Signal Conditioners |  Strain Gauges |  Temperature Controllers | Temperature Labels | Temperature Measurement |  Temperature Transmitters |  Thermistors |  Thermocouple |  Thermocouples |  Thermocouple Cable |  Thermocouple Wire |  Thermowell |  Ultrasonic Flow Meters |  Wireless |  Wireless Video |  Site Map