Cookies on the OMEGA websites
We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
CLOSE
Basket  |  Contact  |  Help  | 
Free Phone 0800 488 488
International+44(0) 161 777 6611
Layer N Banner

Digital Differential Pressure Gauge with High 0.08% Accuracy

DPG409_Diff Series

Digital Differential Pressure Gauge with High 0.08% Accuracy | DPG409_Diff Series

£1,248.40 DPG409-050DWU

CE
  • Wet/Wet Differential Pressure Measurement
  • 5-Point NIST Traceable Calibration certificate
  • Easy to Read Back-lit LCD with 25 mm Digits
  • High 0.08% Accuracy
  • Hi and Lo Alarms Standard
  • MIN/MAX/AVG Reading
  • User Selectable Analogue Output 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA
  • Battery Powered with Long Battery Life
  • IP65 Enclosure
Pressure Gauges - View related products

Description

OMEGA’s DPG409 digital differential pressure gauge incorporates a rugged 316 SS enclosure designed for washdown and marine applications with a precision 0.08% accuracy pressure transducer and 316L SS wetted parts and body. The result is an extremely durable digital pressure gauge. You get all the durabilty and stability of the micromachined silicon sensor in a rugged IP65 enclosure

SPECIFICATIONS
CE Compliant: Meets EN61326-1: 2006 for industrial locations with analogue output cables <3 m and supplied ferrite core
Accuracy (Combined Linearity, Hysteresis and Repeatability): ±0.08% BSL
Storage Temperature: -40 to 82°C
Operating Temperature: -18 to 66°C
Temperature Corrected: Over operating temperature
Thermal Effects (Over Operating Range):
Zero Balance:
    Ranges 10 inH2O to 1 psi (25 mbar to 70 mbar): ±1% span
    Ranges >1 psi (70 mbar): °0.5% span
Span:
    Ranges 10 inH2O to 1 psi (25 mbar to 70 mbar): ±1% span
    Ranges >1 psi (70 mbar): ±0.5% span
Minimum Resistance Between Transducer Body and Any Wire: 100 MΩ @ 50 Vdc
Pressure Cycles: 1 million min
Long Term Stability (1-Yr.): ±0.1% FS typical
analogue Output: User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required)
Note: analogue output is independently scalable
Analogue Output Cable: 2.7 m with ferrite core (included)
Analogue Output Accuracy: 0.08% typical (0.15% max in RF field @ 10V/m
Line/Static Pressure: 500 psi (34.5 bar) max applied to both sides simultaneouly
Proof Pressure (Differential):
    10 inH2O (25 mbar) = 10 times range
    1 psi (70 mbar) = 6 times range
    2.5 to 750 psi (170 mbar to 35 bar) = 4 times range
    1000 psi (70 bar) Range = 3 times range
Hi-Side Containment Pressure (Differential):
10 inH2O to 5 psi (25 mbar to 350 mbar): To 1000 psi (70 bar)
15 to 1000 psi (1 bar to 70 bar): To 3000 psi (200 bar)
Display: 4-digit LCD with user selectable backlighting, (9999 count) 25 mm character height
Sample/Display Rate: User selectable from 0.25 to 10 sec (preset to 1/sec)
Computer Interface: USB connection for set-up, cable included
Power: One 3.6V lithium 4.8 Ah capacity (C cell) included (two included with wireless option)
Battery Life (Typical): Up to 4-years
Enclosure Material: 316 Stainless Steel and ABS centre gasket
Enclosure Finish: Electropolished
Enclosure Environmental Rating: Weatherproof, NEMA 4X (IP65)
Sensor Wetted Parts: 316L Stainless Steel
Pressure Connection: ¼-18 NPT male
Connection Location: Lower
Dimensions:
    Display: 115 D x 89 W x 74 H mm
    Sensor: 72 to 89 mm L below display, 80 mm wide
Weight: 1 kg (2.2 lb) Typical depending upon configuration
Front Panel Functions:
Backlight: Manually turns backlight on/off
Min/Max: Recalls min/max values
Zero/Clear: Zeros display or clears min/max
Software Settings (via USB)
Update Rate: 4 options, 10, 5, 2, 1 times per second
Units: psi, inHg, inH2O, bar, mbar, hPa; must be specified at time of order
Lock: Allows the lock-out of front panel functions
Alarms: User selectable “High” and “Low” alarm limits (open collector)
analogue Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power)
Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min
Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging
Calibrate: Zero and span
Overrange Indication: “_ _ _ _”
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
Wet/Wet Uni-Directional Differential Pressure Models
DPG409-10WDWU
£1,307.12
Availability: 6 weeks
 
0 to 10.00 inH2O Range, 0 to 25 mbar
DPG409-001DWU
£1,307.12
Availability: 6 weeks
 
0 to 1.000 psi Range, 0 to 70 mbar
DPG409-2.5DWU
£1,307.12
Availability: 6 weeks
 
0 to 2.500 Range, 0 to 170 mbar
DPG409-005DWU
£1,248.40
Availability: 6 weeks
 
0 to 5.000 Range, 0 to 350 mbar
DPG409-015DWU
£1,248.40
Availability: 2 weeks
 
0 to 15.00 Range, 0 to 1 Bar
DPG409-030DWU
£1,181.97
Availability: 6 weeks
 
0 to 30.00 Range, 0 to 2 Bar
DPG409-050DWU
£1,248.40
Availability: 2 weeks
 
0 to 50.00 Range, 0 to 3.5 Bar
DPG409-100DWU
£1,248.40
Availability: 6 weeks
 
0 to 100.0 Range, 0 to 7 Bar
DPG409-150DWU
£1,248.40
Availability: 6 weeks
 
0 to 150.0 Range, 0 to 10 Bar
DPG409-250DWU
£1,248.40
Availability: 6 weeks
 
0 to 250.0 Range, 0 to 17.5 Bar
DPG409-500DWU
£1,248.40
Availability: 6 weeks
 
0 to 500.0 Range, 0 to 35 Bar
DPG409-750DWU
£1,248.40
Availability: 6 weeks
 
0 to 750.0 Range, 0 to 50 Bar
DPG409-1KDWU
£1,248.40
Availability: 6 weeks
 
0 to 1000 Range, 0 to 70 Bar
All amounts shown in EUR, GBP, or USD
Note: Comes complete with operator’s manual, battery, set-up and configuration software USB cable, 2.7 m analog output cable with ferrite core and 5-point NIST traceable calibration certificate.

Product Manuals:

Download DPG409 Series Digital Pressure Gauge
Download Quick Start Guide - DPG409 SERIES High Accuracy Digital Pressure Gauge
We noticed you are from the US. Visit your local site for regional offers and live support.