Cookies on the OMEGA websites
We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
CLOSE
Basket  |  Contact  |  Help  | 
Free Phone 0800 488 488
International+44(0) 161 777 6611
Layer N Banner

PTFE Liquid Flow Sensors  - Discontinued

FPR-1500

 | FPR-1500

CE
  • Provides Highly Linear 0 to 5 Vdc Output Signal and Buffered Linear Pulse Output Signal for Totalizing
  • Micro-Liquid Flow Rates as Low as 15 ml/min Can Be Measured with High Precision
  • Usable with a Variety of Low Viscosity Liquids Including Many Corrosive Liquid Chemicals
Turbine, Paddle Wheel & Positive Displacement Flowmeters - View related products

Description

FPR1501 Series flow sensors can measure extremely low flow rates from 15 mL/min. They are suitable for a wide variety of industrial, commercial, and laboratory flow applications.

Because the FPR1501 flow sensors have only PTFE and sapphire wetted surfaces, it is anticipated that they will replace conventional glass tube and ball flowmeters in many applications in which an electrical signal proportional to flow rate is desirable, even in very corrosive applications in which the liquid is low in viscosity (i.e., less than 10 centistokes).

Models use a Pelton-type turbine wheel to determine the flow rate of the liquid. The rotation rate of the turbine wheel is linear over a large dynamic range. The electro-optical system consists of a diode emitting energy in the infrared spectrum. Light energy is interrupted and passed from 8 small holes in the small turbine wheel. This reflected light energy is detected by a photodiode. Thus, as the turbine wheel rotates in response to the liquid flow rate, electrical pulses are generated. Processing circuitry provides a DC voltage output and buffered square-wave output pulses that are proportional to the flow rate.

Tube Fitting:
1/8" tube fittings for flowrates up to 100 ml/min
¼" tube fitting for flow rates from 100 ml/min. to 2 liters/min
3/8" tube fitting for flow rates greater than 2 liters/min.

SPECIFICATIONS
Output Signal: 0 to 5 Vdc, adjustable ±20% (typical) and pulse output from 0 to 300/500 pps (typical) @ 7.5 Vdc peak pulse height-linear
Power Requirements: 12 to 15 Vdc regulated, 50 mA
Standard Sensor Material: PTFE, sapphire, Perfluoroelastomer gasket; PFA compression tube fittings
Pressure Rating: 4 bar (60 psig) max
Temperature Rating: 0 to 70°C (32 to 158°F)
Temperature Sensitivity: ±0.2%/°C
Accuracy: ±1% FS
Repeatability: ±0.2% FS from 20 to 100% of rated max flow
Dimensions: 55.6 x 48.0 x 58.9 mm (2.19 x 1.89 x 2.32") not including fittings
Applicable Liquids: Many low-viscosity (<10 centistokes) liquids; check compatibility with wetted materials; specify liquid when ordering
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
FPR1502
Consult Sales  
Availability: 
 
 
25 to 200 ml/min
FPR1503
Consult Sales  
Availability: 
 
 
50 to 500 ml/min
FPR1500-PW
Consult Sales  
Availability: 
 
 
Power supply 115 Vac to 12 Vdc
DP25B-E
£348.57
Availability: 4 weeks
 
Analog input panel meter with 12 volt excitation
All amounts shown in EUR, GBP, or USD
Note: Note: Maximum differential pressure (delta P) across flow sensor occurs at maximum rated flow using water at 23°C (73°F). At 50% of rated flow,delta P is 0.25 of value at max. rated flow, and, at 20% of rated flow, delta P is 0.04 of value at max. rated flow. Units come with 0.9 m (3') long cable with pigtails and operator’s manual.
 
We noticed you are from the US. Visit your local site for regional offers and live support.