Cookies on the OMEGA websites We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
Differential Pressure Transmitter with two accuracy versions, for dry clean gases.
SPECIFICATIONS Excitation: 12 to 36 Vdc Output: 4 to 20 mA (2 wire) Operating Temp: -29 to 85°C (-20 to 185°F) Compensated Temp: -18 to 72°C (0 to 160°F) Thermal Effects: Zero: 0.015% FS/°F Span: 0.015% FS/°F Proof Pressure: 10 psi Burst Pressure: 50 psi Static Pressure: 100 psi Sensor Type: Capacitance Max Loop Resistance: (Supply voltage - 12) x 50 Ω Calibration Report: NIST calibration at 25, 50, 75 and 100% FS; upscale and downscale provided Response Time: 250 ms Wetted Parts: Dry, clean non-corrosive gases only Enclosure: NEMA 4X (IP65); 137 L x 76 W x 64 mm D (5.4 x 3 x 2.5") Pressure Port: ¼ NPTF Electrical Conn: Screw terminal (two ½ NPTF conduit) Weight: 955 g (2.1 lb)
† All amounts shown in EUR, GBP, or USD Note: Comes with complete operator’s manual. To Order the High Accuracy PX657, (0.15%). See Part Number Builder below.
Part Number Builder
Build Your Part Number Below
Option Descriptions:
(1)
Accuracy select from: 6 for Standard Accuracy 7 for High Accuracy
(2)
Range (inH2O) select from: 0.1 for 0-0.1 0.25 for 0-0.25 0.5 for 0-0.5 01 for 0-1 02 for 0-2 03 for 0-3 05 for 0-5 10 for 0-10 25 for 0-25 50 for 0-50 100 for 0-100 200 for 0-200 0.05B for ± 0.05 0.25B for ± 0.25 0.50B for ± 0.50 01B for ± 1 2.5B for ± 2.5 05B for ± 5 10B for ± 10 25B for ± 25 50B for ± 50 100B for ± 100
Note: All combinations may not be valid, check spec sheet for valid part numbers.